Background Image


Sensor Catalogue

Pic



e-PM : fine particles

PM 10 / PM 2.5
  • Image
  • Image
  • Image

Real-time measurement of airborne particles and fine dust concentration (PM 2.5 PM & 10) as well as temperature and humidity parameters.
e-PM management through Soft'Air software.
Real-time communication over the cellular network

  • Measurement range : PM2.5 0-100µg/m3 & PM10 0-200µg/m3
  • Quantification limit : 5 µg/m3
  • Technology : Light diffraction
  • Communication : GSM / RF
  • Uses : Indoor and outdoor air quality

Download documentation

E-PM AQFeel GSM E-PM AQSense RF
  • Use cases
    Indoor use cases

    Indoor air quality diagnostic : offices, Public buildings, industrial environment…
    Qualification of building IAQ before and after construction and renovation.
    Measure immediately during and after building IAQ crisis.
    Control the efficiency of your air treatment system.
    Information and risk prevention for sensitive people.

    Outdoor use cases

    Observe particle levels of outdoor environments.
    Follow particle levels and estimate the influence of a source (ex : traffic, quarry, metals…).
    Conduct studies prior to the implantation of a facility.
    Urban cartography and planning.

  • Specifications
    GSM : AQ FEEL RF : AQ SENSE
    Range of use (T°C, HR) -5°C… +50°C ǀ 0…95% T>0°C ǀ 0…70% T<0°C
    Accuracy (T°C, HR) ± 0.5°C (from 5 to 40°C) ǀ ± 3% (from 20 to 80% HR)
    Measurement range (PM2.5, PM10) PM 2.5 (0 – 100 µg/m3) - PM 10 (0 – 200 µg/m3); Qualitative beyond
    Technology Light scattering detection
    Communication GSM Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Energy IAQ : Main power
    EAQ : Battery + Solar panel
    Main power or rechargeable batteries
    Measurement periodicity Ajustable ǀ Optimale : 5 min on main power
    Starting system Remotely with Soft’Air software Through magnet – with LED control
    Data M2M data volume : 5 Mo/month in average (periodicity of 10 min) Internal memory : 3 months of measurement (with 30min periodicity)
    Autonomy 10 days without sun (with 10min periodicity) 1 week (with 30min measurement periodicity)
    Box dimension and weight Measurement box : 16 x 16 x 6 (cm) – 0,4 kg
    Homesense + battery : 31*23*18 (cm) – 4,2 kg
    Solar panel + support : 55*32*41 (cm) – 3,0 kg
    16 x 16 x 6 (cm) measurement box - 800 g

e-VOC Industry

Total VOC
  • Image
  • Image
  • Image

Measuring in real time the concentration of total volatile organic compounds (equivalent to isobutylene or other VOCs) as well as the temperature and humidity settings.
Remotely connect up to 20 sensors simultaneously via the wireless network.
Manage your e-VOC through Soft'Air software.

  • Total VOC : 0-200 ppm (isobutylene)
  • Detection limit : 0,1 ppm
  • Technology : PiD
  • Communication : RF

Download documentation

e-VOC Industry
  • Use cases

    Diagnostic of indoor air quality in industrial environments.
    Continuous monitoring of working area atmosphere in industries for worker protection
    Measure immediately during and after building IAQ crisis.
    Control the efficiency of your air treatment system.
    Visualization of dynamic phenomenon.

  • Specifications
    Range of use (T°C, HR) +10°C… +40°C ǀ 30…70%
    Accuracy (T°C, HR) ± 0.5°C (from 5 à 40°C) ǀ ± 3% (de 20 à 80% HR)
    Total VOC Measurement range : 0 – 200 ppm (isobutylene) ; qualitative beyond
    Technology Photo Ionization detection (10.6 eV)
    Detection limit 0,1 ppm in volume
    Uncertainties +/- 5% of the mesure
    Calibration Recommended every 3 months
    Communication Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Energy Main power or rechargeable batteries
    Minimum periodicity 2 min
    Internal memory 1 month measurements (with 10min periodicity)
    Battery life 14 days (with 10min periodicity)
    Starting system Through magnet – with LED control
    Box dimension and weight 16 x 16 x 6 (cm) measurement box - 800 g

e-VOC PPB

Total VOC
  • Image
  • Image
  • Image

Measure in real time indoor Total Volatile Organic compounds (VOCt) (equivalent to isobutylene or other VOC) as well as temperature and relative humidity.
Connect remotely up to 20 sensors simultaneously through RF network.
Configure your e-VOC with Soft’Air software.

  • Rang of use : 0-2000 ppb Isobutylene equivalent
  • Detection limit : 5 ppb
  • Technology : PiD
  • Communication : RF
  • Energy : Main Power

Download documentation

e-VOC ppb
  • Use Cases

    Indoor air quality diagnostic : offices, Public buildings, industrial environment…
    Qualification of building IAQ before and after work construction and renovation.
    Measure immediately during and after building IAQ crisis.
    Control the efficiency of your air treatment system.
    Visualization of dynamic phenomenon.

  • Specifications
    Range of use (T°C, HR) +10°C… +40°C ǀ 30…70%
    Precision (T°C, HR) ± 0.5°C (from 5 to 40°C) ǀ ± 3% (from 20 to 80% HR)
    Total VOC Measurement range : 0 – 2000 ppb (isobutylene) ; qualitative beyond
    Detection limit 5 ppb in volume
    Technology Photo Ionization detection (10.6 eV)
    Uncertainties +/- 2% of the measure + 5 ppb (at constant temperature and humidity)
    Calibration Recommended every 21 days
    Communication Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Energy Main power only
    Minimum periodicity 1 min
    Internal memory 1 month measurements (with 10min periodicity)
    Starting system Through magnet – with LED control
    Box dimension and weight 16 x 16 x 6 (cm) measurement box - 800 g

e-Styrene

Styrene
  • Image
  • Image
  • Image

Measure in real time Styrene concentrations in industrial environment using styrene solvent (boats, composite materials…)
Communicate data with MODBUS protocol.

  • Range of use : 0 – 80 ppm Styrene equivalent
  • Detection limit : 1 ppm
  • Technology : PiD
  • Communication : MODBUS

Download documentation

e-Styrene
  • Use cases

    Continuous monitoring of working area atmosphere in industries for worker protection.
    Automatic air treatment flow regulation based on user defined styrene levels thresholds.
    Saves energy by decreasing ventilation flow rate when Styrene concentration is low.

  • Specifications
    Range of use (T°C, HR) +10°C… +40°C ǀ 30…70%
    Accuracy (T°C, HR) +/- 6% of the measure (min 1 ppm)
    Measurement range (total VOC) 0-80 ppm (styrene equivalent) ; Qualitative beyond
    Detection limit 1 ppm in volume
    Technology Photo Ionization detection (10.6 eV)
    Calibration Recommended every 6 months
    Communication MODBUS
    Energy Continuous power between 7V and 24V
    Minimum periodicity 1 min
    Box dimension and weight 16 x 16 x 6 (cm) - 800 g (measurement box)
    Warranty 1 year

e-NO2

NO2
  • Image

e-NO2

Measure in real time indoor and outdoor Nitrogen Oxide concentration.
Configure your e- NO2 with Soft’air software.

  • Range of use : 0 – 240 ppb
  • Detection limit : 20 ppb
  • Technology : Electrochemical
  • Communication : RF ou GSM

Download documentation

e-NO2
  • Use cases

    Outdoor air quality diagnostic.
    Follow the ammonia levels and the influence of traffic sources.
    Monitor nitrogen oxide levels of underground parkings and tunnels.
    Monitor road traffic sources.

  • Specifications
    Range of use (T°C, HR) -5°C… +40°C | 10…90% HR (non condensing)
    Precision (T°C, HR) < 30% of the mesure
    Measurement range 0-240 pbb
    Quantification limit 20 ppb
    Technology Electrochemical
    Calibration Annual
    Communication GSM
    or
    Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Energy main power, two 5 VDC power outlets
    Internal memory 1 month (with a 10 minute frequency)
    Box dimension and weight 13 x 10 x 5 (cm) - 500 g (communication box)
    D 3,2 x L 6,2 (cm) - 55g (measurement box)

e-H2S

H2S
  • Image

e-H2S

Measure in real time indoor and outdoor hydrogen sulfide concentration.
Configure your e-H2S with Soft’air software.

  • 4 Ranges of use : 0 – 1000 ppb | 0-2000 ppb | 0-20 ppm | 0-200 ppm
  • Detection limits : 10 ppb | 20 ppb | 30 ppb | 200 ppb
  • Technology : Electrochemical
  • Communication : RF or GSM

Download documentation

e-H2S
  • Use cases

    Indoor and Outdoor air quality diagnostic: offices, Public buildings, industrial environment…
    Building qualification before and after acceptance.
    Measure immediately during and after crisis (sick building syndrome).
    Conduct studies prior to the implantation of a facility.
    Control the efficiency of your air treatment system.
    Monitor hydrogen sulfide levels of outdoor environments.
    Follow the hydrogen sulfide levels and the influence of a treatment plant.

  • Specifications
    Range of use (T°C, HR) -20°C… +45°C | 10…90% HR (non condensing)
    Precision (T°C, HR) < 30% of the measure
    Measurement range 0 – 1000 ppb | 0 – 2000 ppb | 0 – 20 ppm | 0 – 200 ppm
    Quantification limit 10 ppb | 20 ppb | 30 ppb| 200 ppb
    Technology Electrochemical
    Calibration Annual
    Communication GSM
    or
    Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Energy 5 VDC/200 mA; 220V/110V
    Internal memory Up to 1 year depending of the use
    Box dimension and weight RF version: 13 x 10 x 5 (cm) - 500 g (communication) +
    D 3,2 x L 6,2 (cm) - 55g (measurement)
    GSM version: 16 x 16 x 9 (cm) - 500 g

e-NH3

NH3
  • Image

e-NH3

Measure in real time indoor and outdoor ammonia concentration.
Configure your e-NH3 through Soft’air software.

  • Range of use : 0 – 25 ppm
  • Detection limit : 0.5 ppm
  • Technology : Electrochemical
  • Communication : RF or GSM
  • Energy : Main power or solar panel

Download documentation

e-NH3
  • Use cases

    Indoor and Outdoor air quality diagnostic : offices, Public buildings, industrial environment.
    Measure immediately during and after crisis (sick building syndrome).
    Conduct studies prior to the implantation of a facility.
    Control the efficiency of your air treatment system.
    Monitor ammonia levels of outdoor environments.
    Follow the ammonia levels and the influence of environmental sources.
    Monitor chronic exposure.

  • Specifications
    Range of use (T°C, HR) -5°C… +40°C | 10…90% HR (non condensing)
    Measurement range 0 -25 ppm
    Quantification limit 0.5 ppm
    Precision (T°C, HR) < 30% of the measure
    Technology Electrochemical
    Communication GSM
    or
    Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Internal memory 1 month (with a 10 minute frequency)
    Energy RF version: main power, two 5 VDC power outlets
    GSM version: main power or batteries + solar panel
    Box dimension and weight RF version: 13 x 10 x 5 (cm) - 500 g (communication) +
    D 3,2 x L 6,2 (cm) - 55g (measurement)
    GSM version : 16 x 16 x 9 (cm) - 500 g
    Calibration Annual

e-O3

O3
  • Image

e-O3

Measure in real time indoor and outdoor Ozone concentration.

  • Range of use : 0 – 500 ppb
  • Detection limit : 1 ppb
  • Technology : GSS Technology
  • Communication : RF or GSM
  • Energy : Main power

Download documentation

e-O3
  • Use cases

    Indoor and Outdoor air quality diagnostic: offices, Public buildings, industrial environment…
    Measure immediately during and after crisis.
    Control the efficiency of your air treatment system.
    Follow the Ozone levels and the influence of traffic sources.

  • Specifications
    Range of use (T°C, HR) 0°C… +40°C | 10…90% HR (non condensing)
    Measurement range 0 - 500 ppb
    Quantification limit 1 ppb
    Precision (T°C, HR) +/- 10% of the measure (min 8 ppb)
    Technology GSS Technology
    Communication GSM
    or
    Radio frequency : 802.15.4 (868MHz)
    Range : up to 400m without barrier, extensible with Repeat’Air signal repeater
    Internal memory 1 month (with a 10 minute frequency)
    Energy RF version : Main power, one 5VDC power outlet (e-relay) and one 12VDC (O3)
    GSM version: main power
    Box dimension and weight RF version: 13 x 10 x 5 (cm) - 500 g (communication)
    13 x 10 x 6 (cm) – 270 g (measurement) GSM version: 16 x 16 x 9 (cm) – 500 g
    Calibration Annual