Next generation particulate matter OEM sensor
Technical specification User guide
NextPM
Next generation pm sensor
PM10, PM2.5, PM1

Accuracy

3 patents
Detection limite lower than 1µg/m3

Maintenance free

 

Up to 10 years lifetime
From -10°C to 70°C, no impact of humidity

Smart

 

Machine learning  algorithms to improve sensor’s performances

Consulting

 

Our team assists you to meet your custom projects

Consulting

Our dedicated team assists you in the definition, implementation and configuration of Next-PM in order to meet your specific requirements

Next generation PM sensor

Accuracy

New optical design to improve PM 10 PM2.5 PM1 measurement

Maitenance free

Up to 10 000 hours of continuous measurement

Extended operating conditions

Supports a wide range of environmental conditions (temp., hygro)

Innovative

3 patents on accuracy, air flow and design

French technology

Designed, developed and made in France

Smart sensor

“Plug and Play” technology  with advanced algorithm processing

Smart building

 

Improve energy efficiency

Smart City

 

For more efficient and citizen friendly cities

Home automation

 

Improve well being, health and environmental awareness

Transportations

 

Cleaner transportations
Better user experience

Industry

 

Improve security and efficiency, Worker protection, Traceability and process optimization

Facility management

 

Fault detection, predictive maintenance, Smart ventilation

Technical specifications

Désignation/ Designation Valeurs/ Values Unités/ Units
 

GENERAL

Technologie de détection / Technology Optique / Optical
Polluants ciblés / Targeted pollutants PM1 – PM2,5 – PM10
Débit d’aspiration forcé / Airflow 2.5 L/min
Dimensions / Size annexe 1 mm
Durée de vie (utilisation continue) / Lifetime >10 000 heures / hour
 

PERFORMANCES

Gamme de détection des particules / Particle Size detection range 0,3 – 10 µm de diamètre / µm diameter
Efficacité de détection sur particules de 0,3 µm /
Detection efficiency with 0.3 µm diameter particles
> 50 %
Gamme de mesure PM10 – PM2,5 – PM1 / Concentration detection range 0 – 1000 µg/m3 (équivalent sable d’Arizona / Arizona sand equivalent)
Limite de détection PM10 / PM10 detection limit < 1 µg/m3 (équivalent sable d’Arizona / Arizona sand equivalent)
Erreur de Linéarité / Linearity error <5 %
Erreur de Répétabilité / Repeatability error <3 %
Rafraîchissement des données / Refresh rate 1 sec.
Temps de chauffe / Warm-up time 10 sec.
Influence de la température  / Temperature influence <0,01 µg/m3/°C
 

SPECIFICATIONS ELECTRIQUES / ELECTRIC SPECIFICATIONS

Alimentation / Power supply 5,0 VDC
Consommation électrique en fonctionnement pour l’optique /
Power consumption in operation
100

250

mA en moyenne

mA max

Consommation électrique en veille / Sleep mode power consumption <1 mA
 

COMMUNICATION 

UART PM1 / PM2.5 / PM10 µg/m3 & pcs/L
 

AUTRES / OTHER

Conditions d’utilisation / Operating conditions -20 à +70 °C
0 – 95 non condensé %
500 à 1500 hPa
Conditions de stockage / Storage conditions -20 à +70 °C
0 – 95 non condensé %
500 à 1500 hPa
 

Réglementation / Certification

Marquage CE*
UL